Professional Concrobium Mold Control Fogger (** Does not include the concrobium mold control shown in the picture- it is for illustration only**)

** Does not include the concrobium mold control shown in the picture- it is for illustration only**

Concrobium Mold Control Solution can be purchased at most big box stores at a good price

This listing is for 1 Pro Mold Control Fogger - This fogger is Made In The USA and Has A 5 Year Mfg Warranty

1 Hp, 120VAC 50/60Hz, 7 amp Optional: 240VAC, 3.5 amp, Three counter-rotating vortex nozzles

Handles both oil- and water-based chemical solutions
(Liquid viscosity and density affect particle size distribution)

0-10 oz/min [0-300 ml/min], adjustable, tank holds 1 gallon [4 liters]

Power head housing and tank - aluminum Tubing - fuel and oil resistant vinylFittings and control valve - brass Nozzle - Celcon

12 Lbs, 5 year warranty


You can use this fogger for other mold mildew products as long as they are labeled for fogging
also can be used for pest control or water misting.

Applying Concrobium Mold Control with a cold (ULV) Fogger is an effective way to eliminate mold and musty smells in large or inaccessible spaces. Fogging is ideal for treating and pre-treating various areas including;

Large spaces e.g. entire rooms, basements, cellars

Hard-to-reach areas e.g. attics, crawlspaces, wall cavities

New home, building or institution construction sites e.g. framed house

How to use fogger

Room Fogging Tips:

If fogging a room with 8’ ceilings, fogger should be placed on stool or bench approx 4’ off the floor for operation. (For 10’ ceilings, place fogger 6’
off the floor). Aim fogger towards one top corner of room – at join line between ceiling and wall.

Start fogging on Med flow rate for 2-3 minutes, then rotate fogger to ensure an even fog (e.g., a quarter turn every 2-3 minutes).
More frequent rotation may be required if run-off or pooling develops.

Each area requires its own treatment considerations re: product quantity, application duration, fogger positioning and rotation technique. It may be
necessary to apply product for a longer period, in certain directions, to compensate for room dimensions e.g. a long narrow room.

Fogger radius/reach is approximately 30 feet; it will be necessary to re- position fogger for rooms with dimensions greater than 60 feet.


Application:

Concrobium Mold Control® is a 100% natural mold-fighting solution that eliminates and prevents mold with no harmful chemicals. A fogger atomizes Concrobium Mold Control into a fine mist that quickly and evenly coats surfaces. Fogging is ideal for treating and pre-treating various surfaces:

Large spaces e.g., entire rooms, basements, cellars Hard-to-reach areas e.g., attics, crawlspaces, wall cavities New home, building or institution construction sites e.g., framed house.

Fogging Objective:

To saturate air with Concrobium Mold Control fog such that the product spreads throughout the target area and coats surfaces with a thin, even layer. Using the fogger to spray surfaces directly from a short distance may lead to over-application, and is not recommended.


Important:

To be effective, Concrobium Mold Control must make direct contact with the moldy surface. If you suspect the presence of hidden mold (e.g. behind walls, under carpets, etc.) you must first expose the moldy surfaces so that the Concrobium fog can land on and coat them. This may include opening up wall cavities, removing wallpaper, lifting carpeting or removing ceiling tiles.


How to fog for Mold:

1. Review Table 1 for approximate fogging time and product required.

2. Remove Fogger power head from tank. Add Concrobium Mold Control to fogger tank. Fasten clamps to secure power head.

3. Install intake air filter to help protect motor from intake of mold spores and moisture. Intake filter installs over the louvers of rear housing of       fogger. Attach the two adhesive backed hook fasteners to 10 and 2 o’clock positions, anchor bottom of filter and stretch elastic over housing. Filters can
   be cleaned and reused should they become soiled.

4. Remove or cover any room contents that may be damaged if wetted e.g., furniture, electroni cs, electrical sources, paper products. Close windows and    doors.

5. Adjust liquid flow rate knob at side of fogger head (Low, Med, High). The liquid flow rate determines the size of the fog droplets formed by the machine.    A Medium flow rate is recommended for application of Concrobium Mold Control. 

6. Position fogger in space being treated and adjust fogger head angle as required to ensure appropriate throw of fogged product. Activate and run fogger    according to “Room Fogging Tips” section on page 2 of this document. Fog target space according to fogging time recommendations in Table 1.

7. Do not over-apply product on surfaces. Run-off and pooling is a sign of over-application.

8. When fogging is complete, open reservoir, remove suction tube from liquid source and operate fogger for one minute with flow rate set at high. This will    remove remaining liquid from fogger’s internal lines.

9. After fogging, allow fog to dissipate for 15-20 minutes. Where possible, wipe off any excess wetness from surfaces, particularly flat, horizontal ones,    with a clean cloth.

10. After fog has dissipated for required time, open windowsand/or ventilate area to allow air exchange.

11. Allow surfaces to dry overnight. Do not rinse. If over- application has occurred, a harmless white residue may remain on surfaces. It may be necessary to     wipe some surfaces clean after drying e.g., glass and mirrors.


Table 1
How to use fogger

Fogger Operation Guidelines:

Use only Concrobium Mold Control with your fogging machine
. Do not
apply any liquid that is hazardous to people, animals or property when atomized into small droplets.
Avoid over-exposure to fog output. While Concrobium Mold Control contains no bleach, ammonia, alcohol, acids or VOCs, highly atomized droplets can be quickly
absorbed by the lungs.

Avoid spending undue time in the target area until the fog has dissipated.

Keep an intake air filter in place during use. This will help prevent dust and fog droplets from entering the unit.

Use only a properly grounded (earthed) three pin electric outlet. The ground wire is an essential safety feature of this product. Do not remove the grounding lug on the power cord. Do not use an ungrounded (3”-to-2”) plug adapter.
An extension cord, if used, must have a continuous ground wire leading to earth.
The amperage rating of an extension cord, if used, must be greater than the amperage shown on the fogger nameplate label. Do not chain two extension cords together
.

Please contact us with any questions