Be confident in your purchase, we're an Authorized PCE Instruments Dealer.
Highlights:
- Air Sampling Device.
- With data logger
- HCHO measurement.
- Bbattery for mobile use.
- 2.8 "TFT display.
- Measurement of mass concentration.
- Data storage on SD card
With the PCE MPC 30 Partical Counter Air Sampler it is possible
to determine the number of particles in the size of 0.3, 2.5 and 10 µm.
In addition to measuring the particles, the Air Sampling Device can also
measure the PM 2.5 and PM 10 mass concentration. The mass concentration
of the Air Sampling Device determines the weight of the particles on
one cubic meter. In
addition to particle measurement, this Device can also determine the
formaldehyde content in ppm. During this HCHO measurement, the
temperature, the ambient humidity and the dew point are determined and
displayed by the Air Sampling Device. As a further important property,
the Air Sampling Device can also store data. It is therefore possible
with the Air Sampling Device to evaluate all measured values after a
measurement.
Features:
- Particle counter, HCHO, temperature measurement
- Measured value recording for later analyzes
- Large 2.8 "LC display, 320 x 240 pixels
- Mass concentration PM 2.5 and PM 10
- Battery for mobile use
- Dew point and wet bulb temperature
Specifications:
- Measurable particle sizes: PM 2.5 and PM 10
- Measuring range: 0 - 2000 µg / m³
- Resolution: 1 µg / m³
- Particle counter -Measurable particle sizes: 0.3, 2.5, 10 µm
- Flow rate 2.83L / min (0.1 ft³)
- Counting efficiency
- 50% at 0.3 µm;
- 100% with particle size> 0.45 µm
- Coincidence error: <5% at 2,000,000 particles per ft³
- Data storage: 5000 data records (micro SD card)
- Counting modes: cumulative, differential, concentration
- HCHO Measuring range: 0.01 - 5.00 ppm
- HCHO Accuracy: ± 5%
- HCHO Resolution: 0.01 ppm
- Measuring range air temperature: 0 - 50 ° C, 32 - 122 ° F
- Measuring range dew point: 0 - 50 ° C, 32 - 122 ° F
- Relative humidity measuring range: 0 - 100% RH
- Air temperature measurement accuracy: 10 - 40 ° C: ± 1 ° C, ± 1.8 ° F Others: ± 2 ° C, ± 3.6 ° F.
- Measuring accuracy dew point temperature: 10 - 40 ° C: ± 1 ° C, ± 1.8 ° F. Others: ± 2 ° C, ± 3.6 ° F
- Relative humidity accuracy:
- 0 - 20% rel. Humidity: ± 5%
- 20 - 80% rel. Humidity: ± 3.5%
- 80 - 100% rel. Fencing: ± 5%
- Operating conditions: 0 - +50 ° C, 10 - 90% rel. humidity, not condensing
- Storage conditions :-10 - +60 ° C, 10 - 90% rel. humidity, not condensing
- Display: 2.8 ", 320 x 240 pixels, backlit color LCD
- Power supply mains adapter:
- Primary: 100 - 240 V AC, 50/60 Hz, 0.6 A.
- Secondary: 9 V DC, 1500 mA
- Power supply battery: 7.4 V, 1200 mAh, 8.88 Wh
- Battery Life: approx. 4 hours in continuous operation
- Battery recharge time: approx. 2 hours with AC adapter
- Dimensions: 240 x 75 x 57 mm
- Weight: 570 g
What's included:
- 1 x Air Sampling Device PCE-MPC 30
- 1 x zero filter
- 1 x battery
- 1 x charger
- 1 x mini USB cable
- 1 x mini tripod
- 1 x hard case
- 1 x instruction manual
|